A wind consortium says it has successfully deployed a power curve measurement procedure that analyzes power output in constantly changing conditions.

The procedure is part of a consortium comprising DTU Wind Energy, DONG Energy, Siemens Wind Power and Avent Lidar Technology. The Danish Energy Technology Development and Demonstration Program provided funding for the three-year effort.

According to Avent, which recently mounted its WindIris LIDAR system atop a Siemens turbine at the 367 MW Walney Wind Farm, the procedure is an upgrade to using met masts, the traditional method to measure power performance.

"Measurements of wind turbine power curves are a key issue for the wind industry," explains Thomas Velociter, CEO at Avent. "But conducting power performance verifications with met-masts is often difficult and extremely expensive, particularly offshore or in onshore complex terrains, which means that verifications and measurements are sometimes skipped all together.

He says that nacelle-mounted LIDARs allow for accurate and affordable measurements, resulting in reduced cost of energy and increased competitiveness.

The technology has been submitted to the expert and standardization groups Measnet and IEA Task 32 in order to be upgraded to an internationally recognized standard. It opens new possibilities for cheaper and more frequent power performance measurements.

According to Avent, the project evolved from a ground-based WINDCUBE LIDAR from Leosphere, which was adapted to be placed on the turbine nacelle for forward looking horizontal measurements. Over the course of the project, several prototypes were developed and tested, and have evolved into a new product called WindIris, which integrates all the elements of the procedure.

The WindIris, manufactured and commercialized by Avent, has been specifically designed for turbine-mounted measurements, which require a product sturdy enough to endure adverse factors, such as nacelle vibrations.

"One of the main challenges was to obtain an equivalent procedure to the IEC 61400-12-1 power performance measurement standard," says Velociter. "To achieve the required level of accuracy and repeatability, the developed procedure accounts for each one of the measurement requirements. For example, it specifies how to measure at hub-height +/- 2.5% at 2.5 rotor diameter in front of the turbine and account for the deviation inherent to the flexibility of the turbine."

Photo caption: The WindIris LIDAR situated atop a Siemens offshore wind turbine.
Photo courtesy of DONG Energy


Trachte Inc._id1770
Latest Top Stories

Quebec Government Postpones Wind Power RFP; No New Date Scheduled

The request for proposals (RFP) is part of an overall 800 MW wind power tranche that will serve as a bridge to the next phase in the province's energy future.


Setting The Record Straight: How Many Birds Do Wind Turbines Really Kill?

Several peer-reviewed studies are more or less in agreement with avian mortality rates caused by wind turbines. However, one study, which is wildly off from the others, is most often cited in the media. Why?


Six Takeaways From The IRS' Start Of Construction Guidance: What You Need To Know

The IRS recently issued guidance to wind developers to further spell out what "start of construction" means. Will you be covered?


Eagle Take Permits For Wind Farms - Will They Fly?

Now that the U.S. Fish and Wildlife Service has issued the first permit allowing the legal take of eagles, can wind developers expect more certainty in the agency's application process?


Despite 2013 Challenges, U.S. Wind Power Reaches All-Time Low Price

In a new report, the U.S. Department of Energy details the highs and lows of the country's wind industry last year, and the agency maintains that the U.S. sector remains strong.

Renewable NRG_id1934
Canwea_id1984
Tower Conference_id1965
UnitedEquip_id1995